Share to
  • Email
  • Facebook
  • X
  • Bluesky
  • Instagram
  • LinkedIn
Share to
  • Email
  • Facebook
  • X
  • Bluesky
  • Instagram
  • LinkedIn
Back to Test Catalogue
Test ID: C1QCOMP SP

Complement Component C1q, Serum/Plasma

Test Overview

Method

Radial Immunodiffusion (RID)

Method Description

This assay quantitates C1q protein. For Immune Complexes by C1q Binding refer to Immune Complexes, Serum/Plasma

Result Included

Complement Component C1q

Specimen

Specimen Type

Serum/Plasma

Containers

Preferred Containers

Gold top (clot activator & gel)

Acceptable Containers

Lavender top (EDTA)

Volume

Sample Volume

1 mL

Minimum Volume

0.1 mL

Collection & Handling

Collection Instructions

Separate serum within one hour of draw time and refrigerate.

Handling Information

Store and send cold or frozen.

Stability

Ambient Refrigerated Frozen
4 days 10 days 29 days

Rejection Criteria

Criteria Specification
Hemolysis Gross
Lipemia Gross
Specimen Room Temp.

Performance & Interpretation

Turnaround Time

13 days

Results

Name
Units
Reference Range
Conversion
  1. Complement Component C1q
    mg/dL
    5.0 - 8.6

    Comment

    Low levels of C1q indicate either increased consumption (catabolism) or decreased synthesis.

Referral Location

Out-of-Country

Interface & Setup

HL7 Interface Codes

Order Code Result Name Result Codes Units
C1QCOMP SP COMPLEMENT COMPONENT C1Q 63545 mg/dL

Test Version

Last Updated

2023-03-21