Share to
  • Email
  • Facebook
  • X
  • Bluesky
  • Instagram
  • LinkedIn
Share to
  • Email
  • Facebook
  • X
  • Bluesky
  • Instagram
  • LinkedIn
Back to Test Catalogue
Test ID: WARFA SP

Warfarin, Serum/Plasma

Test Overview

Method

High performance liquid chromatography-Tandem mass spectrometry (HPLC-MS/MS)

Result Included

Warfarin

Aliases/Synonyms

Coumadin

Specimen

Specimen Type

Avoid gel-separator tubes
Serum
Plasma

Containers

Preferred Containers

No Additive (Red Top)

Acceptable Containers

EDTA (Lavender-Top)

Volume

Sample Volume

1 mL

Minimum Volume

0.2 mL

Specimen Comment

Avoid gel-separator tubes.

Collection & Handling

Handling Information

Store and send cold or frozen.

Stability

Ambient Refrigerated Frozen
30 days 30 days 15 months

Rejection Criteria

Criteria Specification
Specimen Gel tube

Performance & Interpretation

Turnaround Time

12 days

Results

Name
Units
Reference Range
Conversion
  1. Warfarin
    mcg/mL
    Reporting Limit: 0.2 mcg/mL. The reported value may vary based on dilution or weight of the specimen.

Referral Location

Out-of-Country

Interface & Setup

HL7 Interface Codes

Order Code Result Name Result Codes Units
WARFA SP WARFARIN, SERUM/PLASMA 64653 mcg/mL

Test Version

Last Updated

2022-10-04