Back to Test Catalogue

Flecainide, Serum/Plasma

Test ID: FLECA S

Test

Aliases/Synonyms

Tambocor®

Method

Chromatography/Mass Spectrometry

Report Includes

Flecainide

Specimens

Avoid gel separator tubes; Serum; Plasma (EDTA)

Clinical Utility

Monitoring the Flecainide concentration is used to assure compliance and avoid toxicity of this cardiac drug used to treat ventricular tachycardia and premature contractions.

Test Version

8-Sep-2023

Specimen

Specimens

Avoid gel separator tubes; Serum; Plasma (EDTA)

Sample Volume

2.0 mL

Minimum Volume

0.5 mL

Specimen Comment

Avoid gel separator tubes.

Collection & Handling

Collection Instructions

Collect trough specimen within 1 hour prior to next dose.

Handling Information

Store and send frozen.

Stability

Ambient 5 days
Refrigerated 7 days
Frozen 30 days

Rejection Criteria

Specimen Gel-separator tube
Hemolysis Gross
Lipemia Present

Test Version

8-Sep-2023

Performance / Interpretation

Method

Chromatography/Mass Spectrometry

Turnaround Time

11 days

Results

Name Units Reference Range Conversion Factor
Flecainide mcg/mL
  • 0.20 - 0.99

Test Version

8-Sep-2023

Interface / Setup

HL7 Interface Codes

Order Code Result Codes Units
FLECA S 63100FLECAINIDE mcg/mL

Test Version

8-Sep-2023