Test ID: NFLRO S

Neurofilament Light Chain (NfL), Serum/Plasma (Test Site EORLA)

Test Overview

Clinical Utility

Multiple sclerosis, other neurodegenerative disorders, traumatic brain injury.
Neurofilament Light Chain (NfL) is a biomarker of neuraxonal damage and disease activity and is associated with clinical and MRI outcomes in Multiple Sclerosis patients. High or increasing values are suggestive of increased neurodegeneration and increased risk of progression. Normalized or decreasing values are suggestive of a better prognosis and/or effective treatment.

Reference:

M.S. Freedman, S. Gnanapavan, R.A. Booth, P.A. Calabresi, M. Khalil, J. Kuhle, J. Lycke, T. Olsson, C. et al., Guidance for use of neurofilament light chain as a cerebrospinal fluid and blood biomarker in multiple sclerosis management, eBioMedicine 101 (2024) 104970. https://doi.org/10.1016/j.ebiom.2024.104970.

Method

Electrochemiluminescence (ECL)

Analytical Platform

Roche Elecsys

Result Included

Neurofilament Light Chain

Specimen

Specimen Type

Serum
Plasma (Na Heparin)

Important Note: TEST ID: NFLRO S
Non-interfaced clients should specify the Test ID TEST ID: NFLRO S when ordering this test. Not doing so will cause processing delays while ICL ascertains which test you are requesting.
Similar testing is available for clinical use at St. Michael’s Hospital: Neurofilament Light Chain (NfL), Serum/Plasm

Containers

Preferred Containers

Gold top (clot activator & gel)

Acceptable Containers

Red top (no additive); Na Heparin (Green Top)

Volume

Sample Volume

2.0 mL

Minimum Volume

0.5 mL

Pediatric

Volume

1.0 mL

Collection & Handling

Handling Information

Store and send frozen.

Stability

Ambient Refrigerated Frozen
48 hours 7 days >7 days

Stable for up to 4 freeze-thaw cycles.

Performance & Interpretation

Turnaround Time

16 days

Results

Name
Units
Reference Range
Conversion
  1. Neurofilament Light Chain
    pg/mL

    Comment

    Analysis performed by Roche Elecsys. Note, values are significantly (~85%) lower than Simoa.

    NfL is a biomarker of neuroaxonal damage and disease activity and is associated with clinical and MRI outcomes in Multiple Sclerosis patients. High or increasing values are suggestive of increased neurodegeneration and increased risk of progression. Normalized or decreasing values are suggestive of a better prognosis and/or effective treatment. A change in NfL values >30% is beyond the analytical variation and may indicate clinically relevant changes in NfL results when interpreted in conjunction with clinical findings. This test has been validated for clinical use.

    To convert previous Simoa NfL values to Elecsys values please use the following regression equation: NfL(Elecsys) = 0.1227*NfL(Simoa) + 0.1862

    Reference intervals (97.5th percentile) determined using BMI = 27.2 kg/m^2, adapted from Benkert et al. (The Lancet Neurology. 21 (2022) 246–257)

Referral Location

Canada

Interface & Setup

HL7 Interface Codes

Order Code Result Name Result Codes Units
NFLRO S Neurofilament Light Chain 64244 pg/mL

Test Version

Last Updated

2025-03-13