Test Overview
Method
Gas chromatrography-flame ionization detection (GC-FID)
Result Included
Ethylene glycol; Diethylene glycol; Propylene glycol
Specimen
Specimen Type
SerumContainers
Preferred Containers
Red top (no additive)
Acceptable Containers
Gold top (clot activator & gel)
Volume
Sample Volume
1.0 mL
Minimum Volume
0.5 mL
Collection & Handling
Collection Instructions
To evaluate possible toxicity, collect and submit multiple specimens. Collect the first specimen 4 – 6 hours post ingestion and another specimen 3 – 4 hours later. Indicate clearly on the specimen and requisition the collection time for each specimen.
Handling Information
Separate specimens within 2 hours of collection. Ensure that collection times are clearly indicated if submitting multiple specimens. Store and send cold.
Stability
| Ambient | Refrigerated | Frozen |
|---|---|---|
| 2 days | 14 days | 30 days |
Repeated freeze/thaw cycles should be avoided.
Performance & Interpretation
Turnaround Time
3 days
Results
Name
Units
Reference Range
Conversion
-
Ethylene glycolmmol/L< 1.0
Toxic Range: > 3.2 -
Diethylene glycolmmol/L< 1.0
-
Propylene glycolmmol/L< 1.0
Comment
Propylene Glycol is commonly used as a vehicle for many oral and intravenous medications.
Referral Location
Canada
Interface & Setup
HL7 Interface Codes
| Order Code | Result Name | Result Codes | Units |
|---|---|---|---|
| GLYPAN S | Ethylene Glycol | 2910 | mmol/L |
| Diethylene Glycol, Serum | 66290 | mmol/L | |
| Propylene Glycol, Serum | 66291 | mmol/L |
Test Version
Last Updated
2026-04-09