Share to
  • Email
  • Facebook
  • X
  • Bluesky
  • Instagram
  • LinkedIn
Share to
  • Email
  • Facebook
  • X
  • Bluesky
  • Instagram
  • LinkedIn
Back to Test Catalogue
Test ID: ANT ERC

Antimony, Erythrocyte

Test Overview

Method

High resolution sector field inductively coupled plasma-mass spectrometry (HR-SF-ICP-MS)

Result Included

Antimony (µg/L); Antimony (nmol/L)

Specimen

Specimen Type

Erythrocytes

Containers

Preferred Containers

BD 10 ml Na-heparin green top glass Vacutainer (Reference # 366480)

Volume

Sample Volume

3.0 mL

Minimum Volume

1.0 mL

Collection & Handling

Collection Instructions

Collect whole blood in glass contaminant-free tube (e.g. BD 366480). Do not use plastic blood collection tubes since they contain high levels of Antimony.

Handling Information

Separate and transfer erythrocytes to a polypropylene transfer vial within 30 minutes. Store and send frozen.

Additional Information

Trace Metals – Collection of Erythrocytes

Stability

Ambient Refrigerated Frozen
20 days 15 months 15 months

Rejection Criteria

Criteria Specification
Specimen Plastic collection tube

Performance & Interpretation

Turnaround Time

10 days

Results

Name
Units
Reference Range
Conversion
  1. Antimony
    µg/L
    <= 0.50
  2. Antimony
    nmol/L
    <= 4.11

Referral Location

Canada

Test Version

Last Updated

2024-07-19