Back to Test Catalogue

Perampanel LC-MS/MS, Serum/Plasma

Test ID: PERAM

Test

Aliases/Synonyms

Fycompa

Method

High Performance Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS)

Report Includes

Perampanel

Specimens

Avoid gel-separator tubes; Serum; Plasma

Test Location

NMS Labs, Pennsylvania USA

Test Version

26-Jan-2023

Specimen

Specimens

Avoid gel-separator tubes; Serum; Plasma

Collection Containers

Preferred

Red top (no additive)

Acceptable

Lavender top (EDTA)

Sample Volume

1 ml

Minimum Volume

0.3 mL

Specimen Comment

Avoid gel separator tubes

Collection & Handling

Collection Instructions

Promptly centrifuge and separate serum or plasma into a transport tube.

Stability

Ambient 30 days
Refrigerated 30 days
Frozen 25 months

Rejection Criteria

Specimen Gel-separator tubes

Test Version

26-Jan-2023

Performance / Interpretation

Method

High Performance Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS)

Turnaround Time

15 days

Results

Name Units Reference Range Conversion Factor
Perampanel ng/mL
Daily administration of 6 mg perampanel resulted in peak plasma concentrations averaging 460 ng/mL at approximately 1.3 hours post dose. Peak concentrations following a single 12 mg dose of perampanel averaged 800 ng/mL.

Test Location

NMS Labs, Pennsylvania USA

Test Version

26-Jan-2023

Interface / Setup

HL7 Interface Codes

Order Code Result Codes Units
PERAM 62060PERAMPANEL, SERUM/PLASMA ng/mL

Test Version