Greer Labs Inc (House dust) (h1) IgE
Greer Labs Inc (House dust) (h1) IgE, Serum
Test
Method
ImmunoCAP™
Method Description
ImmunoCAP™ assays are based on binding of allergen-specific IgE antibodies in serum to allergen (extract or allergen molecule) coupled in excess to a solid phase. Bound IgE is subsequently detected with enzyme-labeled anti-human IgE, where the fluorescence intensity is proportional to the amount of allergen-specific IgE.
Platform
Phadia
Report Includes
Specimens
Serum
Clinical Utility
In patients suffering from extrinsic asthma, hay fever or atopic eczema, symptoms develop after exposure to specific allergens. This immediate (atopic or anaphylactic) type of allergy is a function of a special type of serum antibodies belonging to the IgE class of immunoglobulins.
Clinician must determine clinical significance of specific IgE result after correlation with clinical exam and history. Detectable levels are present in patients with allergic disease and in approx. 15% of symptomatic healthy persons. Some with classic atopic symptoms may not have detectable levels. Specific IgE may decrease with time and lack of exposure to allergens.
Test Location
Hamilton General Hospital, 237 Barton St E, Hamilton ON L8L 2X2
Test Version
17-Nov-2023
Specimen
Specimens
Serum
Collection Containers
Gold top (clot activator & gel)
Sample Volume
1 mL
Minimum Volume
50 uL
Specimen Comment
Submit enough specimen for number of IgE tests ordered. Each test requires 50 µL and 2 mL is sufficient for 10-12 tests.
Collection & Handling
Handling Information
Store and send frozen
Additional Information
Refer to the list of available IgE Allergen Tests.
Stability
Refrigerated | 3 days |
---|---|
Frozen | 6 months |
Test Version
17-Nov-2023
Performance / Interpretation
Method
ImmunoCAP™
Method Description
ImmunoCAP™ assays are based on binding of allergen-specific IgE antibodies in serum to allergen (extract or allergen molecule) coupled in excess to a solid phase. Bound IgE is subsequently detected with enzyme-labeled anti-human IgE, where the fluorescence intensity is proportional to the amount of allergen-specific IgE.
Platform
Phadia
Turnaround Time
10 days
Results
Name | Units | Reference Range | Conversion Factor | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Greer Labs Inc (House dust) (h1) IgE | kU/L |
|
||||||||||||||||||||||||||||||||||
Clinician must determine clinical significance of specific IgE result after correlation with clinical exam and history. Detectable levels are present in patients with allergic disease and in approx. 15% of symptomatic healthy persons. Some with classic atopic symptoms may not have detectable levels. Specific IgE may decrease with time and lack of exposure to allergens.
|
Test Location
Hamilton General Hospital, 237 Barton St E, Hamilton ON L8L 2X2
Test Version
17-Nov-2023
Interface / Setup
HL7 Interface Codes
Order Code | Result Codes | Units |
---|---|---|
GREERDUST Greer Labs Inc (House dust) (h1) IgE, Serum | 62398ALLERGEN HOUSE DUST: GREER LABS., INC. IGE (KU/L) H1 | kU/L |
Test Version
17-Nov-2023