Test ID: LACPYR WB

Lactate-Pyruvate, Whole Blood

Test Overview

Method

Enzymatic

Result Included

Lactate; Pyruvate; Lactate/Pyruvate Ratio

Specimen

Specimen Type

Whole Blood

Containers

Collection Containers

Green top (lithium or sodium heparin)

Volume

Sample Volume

0.5 mL

Collection & Handling

Collection Instructions

Blood must be added to PCA immediately after collection in order to minimize
degradation of metabolites.

Handling Information

Pipette 0.5 mL of freshly drawn whole blood from Green top tube (on ice) into cold pyruvate tube containing 1 mL of 8% perchloric acid. Mix and spin in cold centrifuge. Aliquot supernatant into clean transport tube. Re-spin in cold centrifuge and remove supernatant into another clean transport container. Freeze immediately at -20°C.

Stability

Frozen
Frozen

If the specimen thaws, it is unsuitable for analysis.

Performance & Interpretation

Turnaround Time

15 days

Results

Name
Units
Reference Range
Conversion
  1. Pyruvate
    mmol/L
    0.06 - 0.22
  2. Lactate
    mmol/L
    0.62 - 2.10
  3. Lactate-Pyruvate Ratio
    ≤ 20.00

Referral Location

Canada

Interface & Setup

HL7 Interface Codes

Order Code Result Name Result Codes Units
LACPYR WB Pyruvate,B 66097 mmol/L
Lactate,B 66098 mmol/L
Lactate/Pyruvate Ratio,B 66099

Test Version

Last Updated