Share to
  • Email
  • Facebook
  • X
  • Bluesky
  • Instagram
  • LinkedIn
Share to
  • Email
  • Facebook
  • X
  • Bluesky
  • Instagram
  • LinkedIn
Back to Test Catalogue
Test ID: MOLY P

Molybdenum, Plasma

Test Overview

Method

High resolution sector field inductively coupled plasma-mass spectrometry (HR-SF-ICP-MS)

Result Included

Molybdenum (µg/L); Molybdenum (nmol/L)

Specimen

Specimen Type

Plasma (K2-EDTA)

Containers

Preferred Containers

BD 6 ml K2-EDTA Royal Blue Vacutainer (Reference # 368381)

Volume

Sample Volume

3.0 mL

Minimum Volume

1.0 mL

Collection & Handling

Collection Instructions

Collect in contaminant-free tube.

Handling Information

Separate as soon as possible and transfer plasma to polypropylene vial. Store and send cold.

Stability

Ambient Refrigerated Frozen
22 days 14 months 14 months

Performance & Interpretation

Turnaround Time

10 days

Results

Name
Units
Reference Range
Conversion
  1. Molybdenum
    µg/L
    0.4 - 2.3
  2. Molybdenum
    nmol/L
    4.7 - 24.0

Test Version

Last Updated

2024-07-19