Share to
  • Email
  • Facebook
  • X
  • Bluesky
  • Instagram
  • LinkedIn
Share to
  • Email
  • Facebook
  • X
  • Bluesky
  • Instagram
  • LinkedIn
Back to Test Catalogue
Test ID: VGCCRIPA S

Voltage-gated Calcium Channel (VGCC) Antibodies by RIPA, Serum

Test Overview

Clinical Utility

Measuring VGCC antibodies is clinically useful in differentiating between neuromuscular disease and a polyneuritis. VGCC antibody-positivity should be followed by tumor investigation. If present, cancer treatment may improve symptoms of LEMS.

Method

Radioimmunoprecipitation Assay (RIPA)

Result Included

Voltage-gated Calcium Channel (VGCC) Antibodies

Aliases/Synonyms

Lambert-Eaton Myasthenic Syndrome

Specimen

Specimen Type

Serum

Containers

Collection Containers

Gold top (SST)

Volume

Sample Volume

5 mL

Minimum Volume

1 mL

Collection & Handling

Handling Information

Store and send frozen (preferred).

Stability

Refrigerated Frozen
7 days 30 days

If the specimen thaws, it is unsuitable for analysis.

Performance & Interpretation

Turnaround Time

30 days

Results

Name
Units
Reference Range
Conversion
  1. Voltage-gated Calcium Channel (VGCC) Antibodies by RIPA
    pmol/L
    Negative: ≤ 30
    Positive: > 30

Referral Location

Canada

Interface & Setup

HL7 Interface Codes

Order Code Result Name Result Codes Units
VGCCRIPA S VGCC Antibodies by RIPA 63359

Test Version

Last Updated

2024-06-07