Back to Test Catalogue
Test ID: ALZD CSF

Alzheimer’s Disease Biomarkers Panel, CSF

Test Overview

Clinical Utility

Please refer to Roche Press Release.

Method

Electrochemiluminescent immunoassay (ECLIA)

Analytical Platform

Roche cobas©

Method Description

Elecsys® AD CSF assay

Result Included

BetaAmyloid42 (ABeta42); Phosphorylated Tau 181 (pTau); Total Tau (Tau)

Specimen

Specimen Type

CSF
Sample must be collected in a Sarstedt FB CSF Collection tube 63.614.625 (blue cap) tube.
These tubes can be ordered from In-Common Laboratories, using the Client Supply Request form.

Containers

Collection Containers

Sarstedt 63.614.625 (blue cap) tube

Volume

Sample Volume

2.5 mL

Minimum Volume

1.5 mL

Collection & Handling

Collection Instructions

Specimens for Alzheimer’s Disease Biomarkers must be collected and handled as described in this downloadable document: Collection & Handling Instructions. Note: CSF must be collected into the Sarstedt 63.614.625 (blue cap) tube. β-amyloid peptides will adhere to plastics such as polystyrene. Failure to follow the recommended collection protocol may result in a falsely low Aβ42 result and contribute to an incorrect diagnosis of Alzheimer’s disease.

Handling Information

Specimens for Alzheimer’s Disease Biomarkers must be collected and handled as described in this downloadable document: Collection & Handling Instructions.

Stability

Ambient Refrigerated Frozen
12 hours 14 days 60 days

Rejection Criteria

Criteria Specification
Specimen Not collected as described

Performance & Interpretation

Turnaround Time

7 days

Results

Name
Units
Reference Range
Conversion
  1. BetaAmyloid42 (ABeta42)
    pg/mL
    > 1030.0
  2. Phosphorylated Tau 181 (pTau)
    pg/mL
    ≤ 27.00
  3. Total Tau (Tau)
    pg/mL
    ≤ 300
  4. pTau:ABeta42 Ratio
    ≤ 0.0230

    Comment

    Compared to CSF concentrations of ABeta42, pTau, and Tau individually, the pTau/ABeta42 ratio has been shown to better correlate with Alzheimer's disease-related pathologic change as measured by amyloid PET scan.
    Please note that improper specimen collection or handling technique may falsely decrease ABeta42 and increase the pTau/ABeta42 ratio.
    Discrepancies in interpretation of the pTau/ABeta42 ratio compared to CSF concentrations of ABeta42, pTau, and/or Tau individually may relate to improper specimen collection/handling, inter-individual variation in beta-amyloid CSF concentration, a disorder related to CSF dynamics, and/or elevation in pTau due to a non-Alzheimer's disease-related pathologic change.
    Clinical correlation is required. For patients with values near cutoffs, interpretation in the context of clinical history is particularly important.

Referral Location

Canada

Interface & Setup

HL7 Interface Codes

Order Code Result Name Result Codes Units
ALZD CSF BetaAmyloid42 (ABeta42),CSF 65228 pg/mL
Phosphorylated Tau 181 (pTau),CSF 65229 pg/mL
Total Tau (Tau),CSF 65230 pg/mL
Alzheimer Interp (ABeta42,pTau,Tau),CSF 65231
pTau:ABeta42 Ratio,CSF 65232
Alzheimer Interp (pTau:ABeta42Ratio),CSF 65233
General Alzheimer's Comment,CSF 65234

Test Version

Last Updated

2025-04-08