Share to
  • Email
  • Facebook
  • X
  • Bluesky
  • Instagram
  • LinkedIn
Share to
  • Email
  • Facebook
  • X
  • Bluesky
  • Instagram
  • LinkedIn
Back to Test Catalogue
Test ID: OVAABSCR

Ovarian Antibody with Reflex to Titer IFA, Serum

Test Overview

Clinical Utility

Ovarian Antibody is found in patients with premature ovarian failure, Addison’s disease, and polyendocrinopathy syndromes.
Reflex: If Ovarian Antibody Screen is positive, then Ovarian Antibody Titer will be performed at an additional charge.

Method

Indirect Immunofluorescence Assay (IFA)

Result Included

Ovarian Antibody Screen; Ovarian Antibody Titer

Specimen

Specimen Type

Serum

Containers

Collection Containers

Gold top (clot activator & gel)

Volume

Sample Volume

1 mL

Minimum Volume

0.3 mL

Collection & Handling

Handling Information

Store and send cold or frozen.

Stability

Ambient Refrigerated Frozen
7 days 14 days 30 days

Rejection Criteria

Criteria Specification
Hemolysis Present
Lipemia Present

Performance & Interpretation

Turnaround Time

10 days

Results

Name
Units
Reference Range
Conversion
  1. Ovarian Antibody Screen
    Negative

    Comment

    Ovarian antibody screen is at 1:5 dilution

  2. Anti-Ovary AB Titer
    < 1:5

Referral Location

Out-of-Country

Interface & Setup

HL7 Interface Codes

Order Code Result Name Result Codes Units
OVAAVSCR ANTI-OVARY ANTIBODY 63047
ANTI-OVARY AB TITER 63048

Test Version

Last Updated

2023-01-26