Test ID: CH50

Complement – Total (CH50), Serum

Test Overview

Clinical Utility

CH50 is a screen for complement deficiencies or significant activation. Measures the relative activity of the total classical pathway (C1-C9).
Complement activity is very labile and reliable results depend on correct handling of the specimen.

Method

Spectrophotometry

Result Included

Complement - Total (CH50)

Aliases/Synonyms

Total Complement Function Assay

Specimen

Specimen Type

Serum

Volume

Sample Volume

2 mL

Minimum Volume

0.5 mL

Collection & Handling

Handling Information

Allow filled tube to clot at 22 – 37°C for 30 – 60 minutes. Centrifuge at room temperature. Aliquot into storage tube and freeze as soon as possible. Store and send frozen.

Additional Information

CH50 may be decreased by: delayed separation of serum, insufficient clotting, prolonged storage at room temperature, use of plasma, presence of immune complexes, cryoglobulins, bacteria or particulates.

Stability

Frozen
14 days

Stable at least 30 days when stored at -80°C

Rejection Criteria

Criteria Specification
Hemolysis Gross
Lipemia Present
Specimen Plasma

Performance & Interpretation

Turnaround Time

6 days

Results

Name
Units
Reference Range
Conversion
  1. Complement - Total
    U/mL
    42 - 95

    Comment

    Analytical range 14 - 105 U/mL. Results less than or greater than these limits will be reported as such.

Referral Location

Canada

Interface & Setup

HL7 Interface Codes

Order Code Result Name Result Codes Units
CH50 CH50 8787 U/mL

Test Version

Last Updated

2026-02-17